Thermal Insulation & Safety and Security & Noise Control | Isıcam Systems K3+ Series

Brand: Isıcam

Isıcam Systems are insulating glass units produced by Isıcam Authorized Manufacturers, which are regularly inspected by Şişecam, using advanced technologies in Şişecam's flat glass plants. It is created by bringing together two or more glass plates under factory conditions to contain dry air or argon gas suitable for ambient pressure. Depending on the properties of the glass used, Isıcam Systems meets one or all of the heat, sun, and noise control, safety, and security requirements with three different series and optional additional features. Isıcam Systems K3+ Series is the triple-glass Isıcam unit, developed for maximum thermal insulation and solar control, using Şişecam Solar Low-E Glass with high-quality heat and solar control coating on the outer glass plate, and Şişecam Low-E Glass with heat control coating on the inner glass plate. In Isıcam K 3+ unit, Solar Low-E coating must always be used on the 2nd surface (the surface of the outer glass facing the cavity) and Low-E coating is on the 5th surface (the surface of the inner glass facing the cavity). In Isıcam K 3+ units, it is recommended that the middle plate be Şişecam Ultra Clear Flat Glass or tempered Şişecam Clear Flat Glass against the risks of thermal breakage. Advantages: • Isıcam Systems K3+ Series provides 4 times better thermal insulation compared to ordinary double glass and 2 times better compared to Isıcam K produced with Şişecam Solar Low-E Glass. • Reduces fuel and air conditioning costs. • Reduces solar heat penetration by 48% compared to ordinary double glass. • Delays fogging. • Depending on the safety requirements, tempered glass can be used on the outer glass by selecting the product suitable for the project from the Şişecam Temperable Solar Low-E Glass range. In this case, the inner glass can be used in the tempered form by selecting the product suitable for the project from the Şişecam Temperable Low-E Glass range.


Please click on "Offer Request" button below to send your offer and detailed information request to the company for the Thermal Insulation & Safety and Security & Noise Control | Isıcam Systems K3+ Series product.


Double glass must be preferred as it suits the needs of every project of different types in the entire climate zone.

All series of Isıcam Systems can be customized and enriched with additional features. Additional features are added to the selected series, meeting all the needs of living spaces and creating happy and peaceful interiors.

Temperable – Heat or Both Heat and Sun Control and Safety;
• Temperable Low-E Glass provides temperature control and safety
• Temperable Solar Low-E Glass provides heat and solar control and safety. This additional feature can only be added to Isıcam S, Isıcam S 3+ and Isıcam K, Isıcam K 3+ products.

Laminated - Safety and Security
Providing Safety and Security, Şişecam Laminated Glass ensures safety and security together by preventing the glass from disintegrating in case of breakage and avoiding possible injuries.

Acoustic Laminated - Noise Control, Safety and Security
Şişecam Acoustic Laminated Glass reduces noise transmission by providing sound insulation, and possesses the safety and security features of Şişecam Laminated Glass, preventing the glass from disintegrating in case of breakage.

3-Glass (Triple Glass) Isıcam Systems –More Effective Thermal Insulation
It is a Triple Glass Isıcam Unit that provides maximum insulation. It provides 4 times the thermal insulation compared to ordinary double glass. Consisting of a minimum of three plates of glass, 3-Glass Isıcam Units meet one or all of the requirements for maximum heat control or both heat and solar control, noise control, safety, and security, depending on the glass used and on additional features to be preferred.

Tinted Glass – Solar Control and Decoration
Şişecam Tinted Flat Glass offers a wide range with various color options. It limits the penetration of daylight into the interior compared to clear flat glass, reduces solar heat penetration, and controls the excessive brightness of the sun. In places where air conditioning is used, it reduces cooling energy consumption, and therefore cooling costs, compared to clear flat glass. For thermal insulation, Tinted Glass must be preferred on the outer glass of the double glass unit, and Low-E Glass, which provides heat control, must be preferred on the inner glass. Due to the risk of thermal breakage, Tinted Glass must be heat-treated (tempered).

Reflective – Solar Control and Decoration
Şişecam Tentesol and Şişecam Tentesol Titanium are reflective glass products that provide solar control, limit the penetration of sunlight and heat into the building, control the brightness of the sun, and reduce cooling energy consumption, and therefore cooling costs, in places where air conditioning is used. Due to their reflective feature, they create a mirror effect when viewed from the direction where the light is strong. For thermal insulation, Reflective Glass must be preferred on the outer glass of the double glass unit, and Low-E Glass, which provides heat control, must be preferred on the inner glass. Due to the risk of thermal breakage, Reflective Glass must be heat-treated (tempered).

3-Glass Isıcam Systems – More Effective Thermal Insulation
It is a Triple Glass (3-Glass) Isıcam Unit that provides maximum insulation. It provides 4 times the thermal insulation compared to ordinary double glass. Consisting of a minimum of three plates of glass, 3-Glass Isıcam Units meet one or all of the requirements for maximum heat control or both heat and solar control, noise control, safety, and security, depending on the glass used and on additional features to be preferred.

National / International Standards That Isıcam Complies With
- TS EN 1279-5 Glass in building - Insulating glass units

National / International Standards That the Raw Materials Comply with Float Glass TS EN 572/2
- Supplied and final cut sizes TS EN 572/8
- Frosted Glass TS EN 572/5
- Tempered Glass EN 12150-2
- Partially Tempered Glass EN 1863-2
- Laminated Glass: EN 14449
- Coated Glass EN 1096
- Heat Soaked Thermally Toughened Tempered Glass EN 14179-2